Should an outside socket have an RCD?
Table of Contents
- Should an outside socket have an RCD?
- Is an outside socket notifiable?
- Is RCD compulsory?
- Do 32A sockets need RCD protection?
- Which is the best outdoor socket?
- How high should outdoor sockets be?
- Is an outdoor socket a special location?
- Can I add sockets myself?
- Is Rcbo better than RCD?
- What code is no RCD on sockets?
- Do you need RCD protection for external sockets?
- Is the outside of a ring protected by a RCD?
- Do you need a RCD for a kitchen light?
- Is it safe to use an outdoor socket?

Should an outside socket have an RCD?
If you use any portable electrical appliances outdoors, they must be protected by a 30mA RCD. The latest IEE Wiring Regulations also state that a new socket - indoors or out - can only be wired into an RCD-protected circuit. ... Some types of socket even have weatherproof covers that will protect it whilst it's in use.
Is an outside socket notifiable?
Under the new, revised regulations, electrical work undertaken in kitchens such as adding a new socket or work outdoors such as installing a new security light will no longer be notifiable unless a new circuit is required.
Is RCD compulsory?
RCDs protect humans against electrocution in a way that fuses and circuit breakers do not. ... If you have a new circuit installed, or a circuit is substantially modified, you may be required to have an RCD fitted under the Building Regulations (Part P) or BS7671 wiring regulations. This is a legal requirement.
Do 32A sockets need RCD protection?
Under the new 18th Edition, all final circuits rated 32A or less need RCD protection to at least 30mA earth leakage. There is no exclusion for 3 phase circuits, so this will cover all 16-amp, 32 amp, single and three phase sockets.
Which is the best outdoor socket?
10 Best Outdoor Smart Plugs
- TglabayunTIEMORE. TIEMORE Outdoor Plug Extension Double Socket IP66 Waterproof with 3m Extension Cable 10~16A. ...
- meross. Smart Plug WiFi Compatible with HomeKit Meross IP44 Outdoor Compatible with WiFi Plug. ...
- Sonoff. ...
- Osram. ...
- TP-Link. ...
- ausyde. ...
- WeMo. ...
- meross.
How high should outdoor sockets be?
Re: height for outdoor outlets 1.
Is an outdoor socket a special location?
Under those regulations and in accordance to BS7671 an outside socket can be installed on an external wall. Outdoors is not considered a special location but the location does present a risk, so reasonable precautions should be made to reduce that risk.
Can I add sockets myself?
As long as the job isn't within a 'special location' such as a bathroom or outdoors, you're also allowed to install additional new light fittings, switches, sockets and even add a single fused spur to an existing circuit (a 'spur' is a new cable and socket run as a branch from an existing socket on the ring main).
Is Rcbo better than RCD?
Whereas an RCD is designed solely to protect against earth leakage and an MCB protects only against over-current, an RCBO protects against both types of fault.
What code is no RCD on sockets?
Code 2 If no form of RCD protection is provided, then you should classify this as a Code 2. For additional information, you may wish to peruse the Electical Safety Council's 'Best Practice Guide 4' for Electrical Installation Condition Reporting.
Do you need RCD protection for external sockets?
No RCD protection is needed on the actual external socket providing that circuit is protected by a 30mA rcd which most modern consumer units have.
Is the outside of a ring protected by a RCD?
The ring is protected by an RCD. malcolmsanford - are you saying that if the socket is in a ring I can't spur off of it?
Do you need a RCD for a kitchen light?
Obviously not an RCD in sight. Only 4 circuits, sockets, lights, immersion, kitchen socket. The last chap had even left info+diagrams in the CU! If I stick a switched fused spur on the sockets upstairs will it need to have an rcd to protect any subsequent wiring for the light?
Is it safe to use an outdoor socket?
Just make sure the outdoor socket is fed from an the circuit like a ring main. Using a ip56 housing and a normal basic socket face is fine best to get it tested if your using equipment outside Rcd tripping in time and electrically safe for disconnection times. Answered 6th Jan 2019